Synthesis of Clinical Correlations and Implications of the Kurjak Antenatal Neurodevelopment Test (KANET)

Authors

  • Sanja Malinac Malojčić Department of Gynecology and Obstetrics Zabok General Hospital and Croatian Veterans Hospital, Croatia Author
  • Siniša Šijanović Faculty of Medicine Osijek, Josip Juraj Strossmayer University of Osijek, Croatia; Osijek Clinical Hospital, Croatia Author
  • Rajko Fureš Department of Gynecology and Obstetrics Zabok General Hospital and Croatian Veterans Hospital, Croatia; Faculty of Dental Medicine and Health Osijek, Josip Juraj Strossmayer University of Osijek, Croatia Author
  • Luka Bulić School of Medicine, University of Zagreb, Croatia Author

DOI:

https://doi.org/10.26332/0x3m4867

Keywords:

ultrasonography, prenatal, pregnancy, high-risk, fetal development, fetal movement

Abstract

Objectives: The Kurjak Antenatal Neurodevelopmental Test (KANET) is a screening tool designed to identify fetuses at risk for neurodevelopmental disorders by assessing fetal motor and behavioral activity through 4D ultrasound. KANET differentiates between normal, borderline, and abnormal fetal behavior, but it cannot be used to diagnose any specific condition. The objective of this review is to synthesize current evidence on the clinical application of KANET and its effectiveness as a screening tool in assessment of fetal neurodevelopment.
Methods: A PubMed search identified 18 relevant studies that evaluated the application of KANET in different maternal risk groups. The studies were analyzed for significant differences in KANET scores between high-risk and low-risk pregnancies.
Results: KANET was effective in distinguishing between normal, borderline, and abnormal fetal behavior in high-risk pregnancies, including those complicated by diabetes, hypothyroidism, and abnormal placental flow. However, KANET is not a diagnostic test and cannot confirm the presence of specific neurological disorders in fetuses from high- and low-risk pregnancies.
Conclusion: KANET is a valuable screening tool for identifying fetuses at risk for neurodevelopmental problems, but further research is needed to refine its use. Importantly, it is not intended to be used as a standalone diagnostic tool for any specific condition.

References

1. Doi M, Usui N, Shimada S. Prenatal Environment and Neurodevelopmental Disorders. Front Endocrinol (Lausanne). 2022 Mar 15;13:860110. doi: 10.3389/fendo.2022.860110.

2. Reddihough DS, Collins KJ. The epidemiology and causes of cerebral palsy. Aust J Physiother. 2003;49(1):7-12. doi: 10.1016/s0004-9514(14)60183-5.

3. Courchesne E, Gazestani VH, Lewis NE. Prenatal Origins of ASD: The When, what, and How of ASD Development. Trends Neurosci. 2020 May;43(5):326-342. doi: 10.1016/j.tins.2020.03.005.

4. Eke CB, Uche EO, Chinawa JM, Obi IE, Obu HA, Ibekwe RC. Epidemiology of congenital anomalies of the central nervous system in children in Enugu, Nigeria: A retrospective study. Ann Afr Med. 2016;15(3):126-132. doi:10.4103/1596-3519.188892

5. Himmelmann K, Ahlin K, Jacobsson B, Cans C, Thorsen P. Risk factors for cerebral palsy in children born at term. Acta Obstet Gynecol Scand. 2011;90(10):1070-1081. doi:10.1111/j.1600-0412. 2011.01217.x

6. Institute of Medicine (US) Committee on Understanding Premature Birth and Assuring Healthy Outcomes; Behrman RE, Butler AS, editors. Preterm Birth: Causes, Consequences, and Prevention. Washington (DC): National Academies Press (US); 2007. C, A Review of Ethical Issues Involved in Premature Birth. Available from: https://www.ncbi.nlm.nih.gov/books/NBK11389/

7. Tinjić S. Experiences and Results of the KANET Test Application in Clinical Practice in Bosnia and Herzegovina: Tuzla.Donald School J Ultrasound Obstet Gynecol 2019; XX (X):1–5

8. Kurjak A, Miskovic B, Stanojevic M, Amiel-Tison C, Ahmed B, Azumendi G, i sur: New scoring system for fetal neurobehavior assessed by three- and four-dimensional sonography. J Perinat Med. 2008;36(1):73-81.

9. Stanojevic M, Talic A, Miskovic B, Vasilj O, Naim Shaddad A, Ahmed B, I sur. An attempt to standardize Kurjak’s antenatal neurodevelopmental test: Osaka consensus statement. Donald School J Ultrasound Obstet Gynecol 2011;5(4): 317-29.

10. Stanojevic M, Antsaklis P, Kadic AS, Predojevic M, Vladareanu R, Vladareanu S. Is Kurjak Antenatal Neurodevelopmental Test Ready for Routine Clinical Application? Bucharest Consensus Statement. Donald School J Ultrasound Obstet Gynecol 2015;9(3):265-69.

11. Hata T, AboEllail MA. Chapter 32—antenatal fetal neurodevelopment test: KANET assessment. In: CR Martin, VR Preedy, R Rajendram , editors. Diagnosis, management and modeling of neurodevelopmental disorders. London: Academic Press (2021). pp. 367–75.

12. Kurjak A, Stanojević M, Andonotopo W, Scazzocchio-Duenas E, Azumendi G, Carrera JM. Fetal behavior assessed in all three trimesters of normal pregnancy by four-dimensional ultrasonography. Croat Med J 2005;46:772–8.

13. Kurjak A, Stanojević M, Predojević M, Laušin I, Salihagić -Kadić A. Neurobehavior in fetal life. Semin Fetal Neonatal Med. 2012;17(6):319-323. doi:10.1016/ j.siny.2012.06.005

14. Bot M, Vladareanu R, Burnei A, Munteanu A, Calo I, Vladareanu S. Monochorionic vs Dichorionic Twins: Kanet Test vs Postnatal Neurodevelopment. Maedica (Bucur). 2020;15(1):61-70. doi:10.26574/maedica.2020.15.1.61

15. Medjedovic E, Kurjak A. Doppler ultrasonography of the uterine artery in correlation with KANET. J Perinat Med. 2020;49(4):455-459. doi:10.1515/jpm-2020-0544

16. Hata T, Kanenishi K, Mori N, et al. Prediction of postnatal developmental disabilities using the antenatal fetal neurodevelopmental test: KANET assessment. J Perinat Med. 2018;47(1):77-81. doi:10.1515/jpm-2018-0169

17. Honemeyer U, Talic A, Therwat A, Paulose L, Patidar R. The clinical value of KANET in studying fetal neurobehavior in normal and at-risk pregnancies. J Perinat Med. 2013;41(2):187-197. doi:10.1515/jpm-2011-0251

18. Hanaoka U, Hata T, Kanenishi K, et al. Does ethnicity have an effect on fetal behavior A comparison of Asian and Caucasian populations. J Perinat Med. 2016;44(2):217-221. doi:10.1515/jpm-2015-0036

19. Hata T, Hanaoka U, Mostafa AboEllail MA, et al. Is there a sex difference in the fetus? behavior? A comparison of the KANET test between male and female fetuses. J Perinat Med. 2016;44(5):585-588. doi:10.1515/jpm-2015-0387

20. Talic A, Kurjak A, Ahmed B, et al. The potential of 4D sonography in the assessment of fetal behavior in high-risk pregnancies. J Maternal Fetal Neonatal Med. 2011;24(7):948-954. doi:10.3109/14767058.2010.534830

21. Antsaklis P, Porovic S, Daskalakis G, Kurjak A. 4D assessment of fetal brain function in diabetic patients. J Perinat Med. 2017;45(6):711-715. doi:10.1515/jpm-2016-0394

22. Athanasiadis AP, Mikos T, Tambakoudis GP, et al. Neurodevelopmental fetal assessment using the KANET scoring system in low and high risk pregnancies. J Maternal Fetal Neonatal Med. 2013;26(4):363-368. doi:10.3109/14767058.2012.695824

23. Talic A, Kurjak A, Stanojevic M, Honemeyer U, Badreldeen A, DiRenzo GC. The assessment of fetal brain function in fetuses with ventriculomegaly: the role of the KANET test. J Maternal Fetal Neonatal Med. 2012;25(8):1267-1272. doi:10.3109/14767058.2011.634463

24. Hata T, Kanenishi K, AboEllail MAM, et al. Effect of psychotropic drugs on fetus behavior in the third trimester of pregnancy. J Perinat Med. 2019;47(2):207-211. doi:10.1515/jpm-2018-0114

25. Dieb A, Salam R, Shaheen D, Shaeer E. Evaluation of fetal neurological behavior in hypothyroid pregnant females - a pilot study. J Maternal Fetal Neonatal Med. 2019;32(16):2617-2621. doi:10.1080/14767058.2018.1442428

26. Miskovic B, Vasilj O, Stanojevic M, Ivanković D, Kerner M, Tikvica A. The comparison of fetal behavior in high risk and normal pregnancies assessed by four dimensional ultrasound. J Maternal Fetal Neonatal Med. 2010;23(12):1461-1467. doi:10.3109/14767051003678200

27. Kurjak A, Talic A, Honemeyer U, Stanojevic M, Zalud I. Comparison between antenatal neurodevelopmental test and fetal Doppler in the assessment of fetal well being . J Perinat Med. 2013;41(1):107-114. doi:10.1515/jpm-2012-0018

28. Predojević M, Talić A, Stanojević M, Kurjak A, Salihagić Kadić A. Assessment of motoric and hemodynamic parameters in growth restricted fetuses - case study. J Maternal Fetal Neonatal Med. 2014;27(3):247-251. doi:10.3109/14767058.2013.807241

29. Abo-Yaqoub S, Kurjak A, Mohammed AB, Shadad A, Abdel- Maaboud M. The role of 4-D ultrasonography in prenatal assessment of fetal neurobehaviour and prediction of neurological outcomes. J Maternal Fetal Neonatal Med. 2012;25(3):231-236. doi:10.3109/14767058.2011.568552

30. Kurjak A, Talic A, Stanojevic M, et al. The study of fetal neurobehavior in twins in all three trimesters of pregnancy. J Maternal Fetal Neonatal Med. 2013;26(12):1186-1195. doi:10.3109/14767058.2013.773306

31. Kurjak A, Abo-Yaqoub S, Stanojevic M, et al. The potential of 4D sonography in the assessment of fetal neurobehavior--multicentric study in high-risk pregnancies. J Perinat Med. 2010;38(1):77-82. doi:10.1515/jpm.2010.012

32. Avci R, Whittington JR, Blossom SJ, et al. Studying the Effect of Maternal Pregestational Diabetes on Fetal Neurodevelopment Using Magnetoencephalography. Clin EEG Neurosci. 2020;51(5):331-338. doi:10.1177/1550059420909658

33. Biete M, Vasudevan S. Gestational diabetes mellitus: Impacts on fetal neurodevelopment, gut dysbiosis, and the promise of precision medicine. Front Mol Biosci. 2024;11:1420664 .

34. Yan S, Wang Y, Chen Z, Zhang F. Chorionicity and neurodevelopmental outcomes in twin pregnancy: a systematic review and meta-analysis. J Perinatol. 2023;43(2):133-146. doi:10.1038/s41372-022-01534-y

35. Tosello B, Garbi A, Blanc J, et al. The impact of chorionicity on pregnancy outcome and neurodevelopment at 2 years old among twins born preterm: the EPIPAGE-2 cohort study. BJOG. 2021;128(2):281-291. doi:10.1111/1471-0528.16170.

Downloads

Published

2025-12-30